← News & Promotions

News

What Is a Spider Tent? Structure, Size and Uses

A steel frame spider tent (not inflatable) uses two crossing arches on four legs. Wild Duck's Spider Tent: 6 x 6 m room, 3.75 m peak, 100 km/h wind rating.

7 min read
Share
3D render of a spider tent with a cross arch frame on a timber deck in a garden Wild Duck Glamping Tent
The Spider Tent open on four sides over a raised timber deck (3D render) Wild Duck Glamping Tent
3D render of the spider tent front with its wide arched wing Wild Duck Glamping Tent
Front view: a wide arched wing you can see straight through (3D render) Wild Duck Glamping Tent
In this article 8 sections
  1. Spider tent at a glance
  2. How is a spider tent built?
  3. Spider tent specifications
  4. One frame, several layouts
  5. Spider tent vs geodesic dome vs event tent
  6. Which projects suit a spider tent?
  7. What do you need before installing a Spider Tent?
  8. Spider tent FAQ

A spider tent is a glamping dome built from two curved steel arches that cross each other at right angles. In the Wild Duck Glamping Tent Spider Tent, the point where the two arches meet forms a 3.75 m high peak, four frame legs anchor to the floor at the corners, and underneath is a 6 x 6 m room with no central column. The tent is rated for 100 km/h winds, takes about 56 hours to install with a crew of 5, and needs no foundation digging.

The name comes from its silhouette: four arched legs reaching down to the corners, like a spider. Unlike the inflatable spider tents used at events, the Wild Duck Spider Tent has a galvanized steel frame and is built as a long term guest room. This article explains how the Spider Tent is built, its technical specifications, the layouts it supports, and when to choose it over a geodesic dome or an event tent.

Spider tent at a glance

  • Structure cross arch dome, two arches intersecting at right angles, four legs
  • Main space 6 x 6 m room, no central column
  • Height 2.3 m ceiling, 3.75 m peak
  • Frame galvanized steel
  • Roof opaque white PVDF fabric, partly translucent
  • Walls and doors optional, blackout PVC walls and clear PVC doors with insect mesh
  • Wind rating 100 km/h (0.5 kN/m²), equivalent to a Beaufort force 11 storm
  • Installation about 56 hours, 5 workers, no foundation digging
  • Service life 5 to 10 years

How is a spider tent built?

The Spider Tent has three main parts: the load bearing cross arch frame, the tensioned fabric roof over it, and the base anchors that fix the frame to the floor. The drawing below separates each part.

Sketch drawing of the Spider Tent: axonometric view, front elevation, floor plan and frame diagram
Blueprints for the Wild Duck Glamping Spider Tent

Galvanized steel cross arch frame

Galvanized steel cross arch frame

The frame is two curved steel arches that cross at the top, tied together with diagonal braces. Because the arches brace each other along two axes, the frame is self supporting with no central pole and no guy ropes reaching far out. All steel is galvanized to resist rust when the tent stands outdoors all year.

Tensioned PVDF roof

The roof is a single tensioned membrane that covers the whole frame, follows the curve of both arches and forms four arched wings on four sides. The opaque white PVDF lets part of the daylight through, so the interior is bright without glare. For a view of the sky, the roof can be switched to a fully translucent fabric.

Base anchors and floor

The four legs bolt into base anchors on the floor. This lets the Spider Tent stand on a raised timber deck or a level concrete slab with no foundation digging, and it can be taken down and moved later. The deck, foundation and lifting equipment are not part of the tent package and are prepared by the owner to suit the site.

Spider tent specifications

ItemSpecification
Room size6 x 6 m
Floor sizeNot fixed, depends on the wing layout
Ceiling height2.3 m
Peak height3.75 m
Wind rating100 km/h (0.5 kN/m²), Beaufort force 11
Permitted load1,000 kg
Installation time56 hours, 5 workers
FrameGalvanized steel
RoofOpaque white PVDF, partly translucent (fully translucent option)
WallsOpaque white PVC, 100% blackout
Doors and windowsTriple layer clear PVC with insect mesh
Foundation, lifting equipment, transportNot included
Service life5 to 10 years

The full grouped specification table is on the Spider Tent product page.

Spider Tent sketch: 6 x 6 m room, 3.75 m peak, galvanized steel frame, PVDF roof.

One frame, several layouts

The four arched wings of the Spider Tent can be left open or closed in, depending on the purpose. With the same frame, an operator can set it up in several ways.

Open on all four sides

Without walls, the Spider Tent becomes an airy domed canopy over a timber deck. This suits an outdoor lounge, a dining area, a bar, a welcome area or a small party space inside a resort. Breezes pass through from all four directions while the roof keeps off sun and rain.

Closed in as a guest suite

With PVC walls and doors fitted to the wings, the tent becomes an enclosed guest room. The central 6 x 6 m space works as a shared living area, and the wings around it can hold sleeping, living or bathroom zones without internal partitions. Wing length, interior zoning and fabric color are all made to suit the site plan and the project’s branding.

Natural ventilation

The raised roof where the two arches cross creates a stack effect: warm air rises to the top while the four wings catch breezes from several directions. The interior stays airy even when the walls are closed.

Spider Tent sketch: 6 x 6 m room, 3.75 m peak, galvanized steel frame, PVDF roof.

Spider tent vs geodesic dome vs event tent

All three have a column free floor, but their shapes and purposes differ:

CriteriaSpider TentGeodesic domeEvent Tent
StructureTwo crossing steel arches, four legsTriangulated strut grid forming a sphereModular frame, extended bay by bay
Size6 x 6 m room4 to 30 m diameterStandard 6 x 12 m floor, extendable
Peak height3.75 mDepends on diameter5 m
ExteriorFour arched wings, open or enclosedEnclosed, white or clear membraneBox shape with pitched roof and side walls
Best forGlamping suites, lounges, outdoor diningBrand launches, photo spots, spherical guest roomsWeddings, conferences, large events

For hundreds of guests, the Event Tent or a large geodesic dome such as the 12 m dome at Thiso Mall Sala is a better fit. The Spider Tent shines at single room scale: large enough for a family or a small group, with a distinctive domed shape that reads as a small building rather than a tent.

Which projects suit a spider tent?

  • Flagship glamping suites: the cross arch silhouette stands out among other tent models and easily becomes a signature of the site.
  • Family rooms: the wings separate sleeping from living areas without partitions.
  • Extended stays: an open, clearly zoned interior that stays comfortable for many days.
  • Outdoor lounges and dining: left open on four sides on a deck by the pool, a lawn or a garden.

What do you need before installing a Spider Tent?

  1. A level base: a raised timber deck or concrete slab large enough for the four legs and the wings.
  2. Access for vehicles and equipment: a route for the truck carrying the frame and fabric. Fitting the roof may need scaffolding, a trolley or a crane. Transport and lifting equipment are not part of the tent package.
  3. Installation time: about 56 hours with a crew of 5 per tent.
  4. Power and water: if the tent is closed in as a guest suite with a bathroom, plan power, water supply and drainage in advance.

Send your site plan to Wild Duck for advice on wing layout and leg positions.

Spider tent FAQ

What is a spider tent?

A spider tent is a glamping dome made of two galvanized steel arches crossing at right angles, with four legs anchored at the corners and a tensioned PVDF roof over the frame. In the Wild Duck Spider Tent the main space is 6 x 6 m with no central column.

Why is it called a spider tent?

The name comes from its shape: two curved arches cross at the top and spread down to four anchored legs at the corners, so the tent looks like a spider. It is a steel frame tent, not an inflatable spider tent like many event models.

How big is the Spider Tent?

The main room is 6 x 6 m, with a 2.3 m ceiling and a 3.75 m peak. The total floor area is not fixed and depends on the length and layout of the wings.

Can a spider tent withstand strong wind?

The Spider Tent is rated for 100 km/h winds (0.5 kN/m²), equivalent to a Beaufort force 11 storm, with a permitted load of 1,000 kg. The two crossing arches brace each other along two axes, which makes the frame stiffer than single arch models.

Does it need a foundation?

No foundation digging is needed. The legs bolt into base anchors on a raised timber deck or a level concrete slab, and the tent can be taken down and relocated.

How long does installation take?

About 56 hours with a crew of 5. Actual time depends on the site, the deck preparation and the number of tents in the project.

How long does a Spider Tent last?

The service life is 5 to 10 years. The galvanized steel frame resists rust and the fabric is easy to clean, keeping maintenance costs low.

How much does a spider tent cost?

The price depends on the number of tents, the fabric, whether walls and doors are fitted, and extras such as a timber deck. Send your project details through the Contact page or the quote button on the Spider Tent page, and Wild Duck will reply within 24 business hours.

Planning a Spider Tent for your resort?

Send your site plan, number of tents and intended use. Wild Duck will suggest a wing layout and quote within 24 business hours.

Get a Spider Tent quote
Share this article
Enlarged photo
Zalo
Back to top

Current offers